CLINICAL EVALUATION OF THE EFFECTIVENESS OF AN INDIVIDUALIZED VOLUMETRIC NOZZLE OF A LOCAL EVACUATION SYSTEM FOR REDUCING THE MICROBIAL LOAD OF DENTAL AEROSOL DURING TOOTH PREPARATION
DOI:
https://doi.org/10.32782/3041-1394.2026-2.7Keywords:
dental aerosol, high-volume evacuation, tooth preparation, airborne microbial contamination, suction device, prosthodonticsAbstract
Introduction The generation of bioaerosols during dental procedures constitutes a significant occupational and biological hazard, posing potential risks to both patients and healthcare personnel. Objective. To evaluate the clinical effectiveness of an individualized volumetric high-volume evacuation attachment in reducing airborne microbial contamination during tooth preparation for fixed dental prostheses. Materials and methods. A pilot randomized controlled clinical study included 20 patients aged 40–65 years undergoing high-speed tooth preparation. Participants were allocated to conventional high-volume evacuation (n = 10) or high-volume evacuation with a patented individualized volumetric attachment (n = 10). Airborne microbial contamination was assessed by passive sedimentation using 25 Petri dishes containing tryptic soy agar: five background samples and ten samples for each evacuation system. Plates were exposed for 60 min, incubated at 37 °C for 24 h, and microbial concentrations were calculated using Omeliansky’s formula. Group differences were evaluated using the Kruskal–Wallis test. Results. Mean background microbial concentration was 115.24 ± 21.52 CFU/m³. Concentrations were 323.45 ± 16.39 CFU/m³ with the individualized attachment and 474.05 ± 36.42 CFU/m³ with conventional evacuation. The overall difference was significant (H(2) = 21.03; p < 0.001; ε² = 0.865). Compared with the conventional device, the individualized attachment reduced microbial contamination by 150.59 CFU/m³, corresponding to a 31.77% relative reduction (adjusted p = 0.0045; Cliff’s δ = –1.00). Conclusions. The individualized volumetric high-volume evacuation attachment significantly reduced viable airborne aerobic microorganisms during tooth preparation compared with a conventional suction cannula. Optimization of suction geometry may strengthen source-control strategies within multimodal dental infection prevention.
References
Holliday R., Allison J.R., Currie C.C. et al. Evaluating contaminated dental aerosol and splatter in an open plan clinic environment: implications for the COVID-19 pandemic. Journal of Dentistry. 2021. Vol. 105. Art. 103565. DOI: https://doi.org/10.1016/j.jdent.2020.103565.
Malmgren R., Välimaa H., Oksanen L. et al. High-volume evacuation mitigates viral aerosol spread in dental procedures. Scientific Reports. 2023. Vol. 13. Art. 18984. DOI: https://doi.org/10.1038/s41598-023-46430-3.
Kim M.J., Kuroda M., Kobayashi Y., Yamamoto T., Aizawa T., Satoh K. Visualization of airborne droplets generated with dental handpieces and verification of the efficacy of high-volume evacuators: an in vitro study. BMC Oral Health. 2023. Vol. 23. Art. 976. DOI: https://doi.org/10.1186/s12903-023-03725-1.
Matys J., Gedrange T., Dominiak M., Grzech-Leśniak K. Quantitative evaluation of aerosols produced in the dental office during caries treatment: a randomized clinical trial. Journal of Clinical Medicine. 2023. Vol. 12, No. 14. Art. 4597. DOI: https://doi.org/10.3390/jcm12144597.
Graetz C., Hülsbeck V., Düffert P. et al. Influence of flow rate and different size of suction cannulas on splatter contamination in dentistry: results of an exploratory study with a high-volume evacuation system. Clinical Oral Investigations. 2022. Vol. 26, No. 9. P. 5687–5696. DOI: https://doi.org/10.1007/s00784-022-04525-7.
Graetz C., Düffert P., Heidenreich R. et al. Spray mist reduction by means of a high-volume evacuation system – results of an experimental study. PLOS ONE. 2021. Vol. 16, No. 9. Art. e0257137. DOI: https://doi.org/10.1371/journal.pone.0257137.
Shahdad S., Patel T., Hindocha A. et al. The efficacy of an extraoral scavenging device on reduction of splatter contamination during dental aerosol generating procedures: an exploratory study. British Dental Journal. 2020. DOI: https://doi.org/10.1038/s41415-020-2112-7.
Holloman J.L., Mauriello S.M., Pimenta L., ArnoldR.R. Comparison of suction device with saliva ejector for aerosol and spatter reduction during ultrasonic scaling. The Journal of the American Dental Association. 2015. Vol. 146, No. 1. P. 27–33. DOI: https://doi.org/10.1016/j.adaj.2014.10.001.
Kumbargere Nagraj S., Eachempati P., Paisi M., Nasser M., Sivaramakrishnan G., Verbeek J.H. Interventions to reduce contaminated aerosols produced during dental procedures for preventing infectious diseases. Cochrane Database of Systematic Reviews. 2020. No. 10. Art. CD013686. DOI: https://doi.org/10.1002/14651858.CD013686.pub2.
Saini R.S., Binduhayyim R.I.H., Mosaddad S.A., Heboyan A. Strategies for preventing aerosol-generated microbial contamination in dental procedures: a systematic review and meta-analysis. American Journal of Infection Control. 2025. Vol. 53, No. 5. P. 638–647. DOI: https://doi.org/10.1016/j.ajic.2025.02.001.
Centers for Disease Control and Prevention. Summary of Infection Prevention Practices in Dental Settings: Basic Expectations for Safe Care. Atlanta : CDC, 2024.
Centers for Disease Control and Prevention. Best Practices for Personal Protective Equipment in Dental Settings. Atlanta : CDC, 2024. Оновлено 15 травня 2024 р.
Круковський І.О., Комариця О.Й. Об’ємна насадка для евакуації аерозолів, що утворюються під час стоматологічних процедур : патент України на корисну модель № 163549, МПК A61C 17/08, A61C 17/00. № u202503773 ; заявл. 05.08.2025 ; опубл. 08.07.2026. Бюл. № 27/2026. URL: https://sis.nipo.gov.ua/uk/search/detail/1933261/.